- Less coil
- Valves have a pilot operated design that shifts the refrigerant flow to either the normal condenser or the reclaim condenser based on the heating requirements of the application
- B-type, normal (outdoor) Condenser de-energized
- Three-way pilot eliminates costly high to low-side leaks
- B-type reduces total installed cost by eliminating need for normally open solenoid valve on systems requiring reclaim condenser pump out
- High capacity at minimum pressure drop
- Tight synthetic main port seating
- Easily-mounted in vertical or horizontal line to simplify piping requirements
- Proven performance backed by Sporlan service, engineering and technical support
- 10 W power rating
Heat reclaim can significantly lower energy costs. Heat reclaim is best described as the process of reclaiming heat that would normally be rejected by an outdoor condenser. Typically, the refrigerant is diverted to an air handler in an area that requires heat. One of the older applications of heat reclaim is in a supermarket, since a supermarket has a constant supply of heat removed from the many refrigerated display fixtures and coolers. Today there are many cost-effective applications of heat reclaim in refrigeration, air conditioning, dehumidification and heat pump systems.
Brand
Parker Hannifin - Sporlan
Nominal Size
1-5/8 in
Connection Type
ODF Solder
Pressure Rating
450 psi, 300 psi Differential Rated
Orifice Size
1-1/4 in
Coil Type
MKC-1
Number of Ports/Ways
3-Way
Dimensions
8.38 in L x 13.57 in W